1、准备

例:两台192.168.219.146(主), 192.168.219.147(从), 域名www.panyangduola.com

主、从DNS服务器均需要安装bind、bind-chroot、bind-utils

yum -y install bind bind-utils bind-chroot

如果防火墙开启,配置防火墙,添加服务(防火墙已禁用则忽略)

firewall-cmd --permanent --add-service=dns
firewall-cmd --reload

2、主DNS服务器(192.168.219.146)配置

编辑配置文件

vim /etc/named.conf

找到其中两行

listen-on port 53 { 127.0.0.1; };
allow-query { localhost; };

修改为

listen-on port 53 { any; };
allow-query { any; };

2-1、配置正向解析

编辑文件/etc/named.rfc1912.zones,在末尾添加需要解析的域

vim /etc/named.rfc1912.zones
zone "panyangduola.com" IN {
  type master;
  file "data/panyangduola.com.zone";
};

创建panyangduola.com.zone解析域

vim /var/named/data/panyangduola.com.zone
$TTL 3600
$ORIGIN panyangduola.com.
@  IN  SOA panyangduola.com. admin.panyangduola.com. (
  2018042101
  1D
  1H
  1W
  3H
)
@  IN  NS  ns1.panyangduola.com.
@  IN  NS  ns2.panyangduola.com.
ns1  IN  A  192.168.219.146
ns2  IN  A  192.168.219.147
www  IN  A  192.168.219.146
web  IN  CNAME www

2-2、配置反向解析

编辑文件/etc/named.rfc1912.zones,在末尾添加需要解析的域

vim /etc/named.rfc1912.zones
zone "219.168.192.in-addr.arpa" IN {
   type master;
   file "data/219.168.192.zone"; 
};

创建219.168.192.zone解析域

vim /var/named/data/219.168.192.zone
$TTL 3600
$ORIGIN 219.168.192.in-addr.arpa.
@  IN  SOA panyangduola.com. admin.panyangduola.com. (
  2018042101
  1D
  1H
  1W
  3H
)
@  IN  NS  ns1.panyangduola.com.
@  IN  NS  ns2.panyangduola.com.
146  IN  PTR  ns1.panyangduola.com.
147  IN  PTR  ns2.panyangduola.com.
146  IN  PTR  www.panyangduola.com.

2-3、对DNS配置文件进行一下语法检查:

cd /etc
named-checkconf named.conf
named-checkconf named.rfc1912.zones
cd /var/named/data
named-checkzone panyangduola.com panyangduola.com.zone
named-checkzone 219.168.192.in-addr.arpa 219.168.192.zone

2-4、编辑/etc/resolv.conf,添加

vim /etc/resolv.conf
search localdomain
nameserver 192.168.219.146

2-5、如果2-3步骤没有错误发生的话,启动named服务

重启named

systemctl restart named

查看状态

systemctl status named

2-6、检查主DNS服务器解析是否成功

ping命令验证

ping -c 4 www.panyangduola.com
nslookup命令验证
nslookup
>www.panyangduola.com
nslookup
>192.168.219.146

3、从DNS服务器(192.168.219.147)配置

编辑named.conf文件

vim /etc/named.conf

找到其中两行  

listen-on port 53 { 127.0.0.1; };   
allow-query { localhost; };

修改为

listen-on port 53 { any; };
allow-query { any; };

3-1、修改主DNS服务器(192.168.219.146)的配置/etc/named.rfc1912.zones

vim /etc/named.rfc1912.zones
zone "panyangduola.com" IN {
  type master;
  file "data/panyangduola.com.zone";
  allow-transfer {192.168.219.147;};
  notify yes;
  also-notify {192.168.219.147;};
};
zone "219.168.192.in-addr.arpa" IN {
  type master;
  file "data/219.168.192.zone";
  allow-transfer {192.168.219.147;}; 
  notify yes; 
  also-notify {192.168.219.147;}; 
};

3-2、配置从DNS服务器(192.168.219.147)正向解析

编辑文件/etc/named.rfc1912.zones,在末尾添加需要解析的域

vim /etc/named.rfc1912.zones
zone "panyangduola.com" IN {
  type slave;
  file "data/panyangduola.com.zone";
  masters { 192.168.219.146; };
};

创建panyangduola.com.zone空文件

touch /var/named/data/panyangduola.com.zone

设置所有者  

cd /var/named/data
chown named:named panyangduola.com.zone

3-3、配置从DNS服务器(192.168.219.147)反向解析

在文件/etc/named.rfc1912.zones中添加

vim etc/named.rfc1912.zones
zone "219.168.192.in-addr.arpa" IN {
 type slave;
 file "data/219.168.192.zone";
 masters { 192.168.219.146; };   
};

创建空文件219.168.192.zone

touch /var/named/data/219.168.192.zone

设置所有者

cd /var/named/data
chown named:named 219.168.192.zone

3-4、对DNS配置文件进行一下语法检查:

cd /etc
named-checkconf named.conf
named-checkconf named.rfc1912.zones

3-5、编辑/etc/resolv.conf,添加

vim /etc/resolv.conf
search localdomain
nameserver 192.168.219.147

3-6、如果3-4步骤没有错误发生的话,启动named服务

重启named

systemctl restart named

查看状态

systemctl status named

3-7、查看文件/var/named/data/panyangduola.com.zone和/var/named/data/219.168.192.zone是否有二进制数据

cat /var/named/data/panyangduola.com.zone
cat /var/named/data/219.168.192.zone

3-8、检查从DNS服务器解析是否成功

ping命令验证
ping -c 4 www.panyangduola.com
nslookup命令验证
nslookup
>192.168.219.147

总结

以上所述是小编给大家介绍的centos7.x 部署主、从DNS服务器问题,希望对大家有所帮助,如果大家有任何疑问请给我留言,小编会及时回复大家的。在此也非常感谢大家对网站的支持!
如果你觉得本文对你有帮助,欢迎转载,烦请注明出处,谢谢!

标签:
centos7,部署,DNS服务器,centos7,部署服务器

免责声明:本站文章均来自网站采集或用户投稿,网站不提供任何软件下载或自行开发的软件! 如有用户或公司发现本站内容信息存在侵权行为,请邮件告知! 858582#qq.com
评论“centos7.x 部署主、从DNS服务器问题”
暂无“centos7.x 部署主、从DNS服务器问题”评论...

RTX 5090要首发 性能要翻倍!三星展示GDDR7显存

三星在GTC上展示了专为下一代游戏GPU设计的GDDR7内存。

首次推出的GDDR7内存模块密度为16GB,每个模块容量为2GB。其速度预设为32 Gbps(PAM3),但也可以降至28 Gbps,以提高产量和初始阶段的整体性能和成本效益。

据三星表示,GDDR7内存的能效将提高20%,同时工作电压仅为1.1V,低于标准的1.2V。通过采用更新的封装材料和优化的电路设计,使得在高速运行时的发热量降低,GDDR7的热阻比GDDR6降低了70%。